Vs sup2t 10g datasheet. 1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G xxx 2 48 CEF720 48 port 1000mb SFP WS-X6848-SFP xxx. Vs sup2t 10g datasheet

 
1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G xxx 2 48 CEF720 48 port 1000mb SFP WS-X6848-SFP xxxVs sup2t 10g datasheet  191

Our super fast turnaround times and high quality stock located all. They enable security, mobility, application performance, video, and energy savings over an infrastructure that supports resiliency, virtualization, and. Cisco Nexus 7000 Series Supervisor2 Module. The family includes three modules: the Catalyst 6800 32-port, 16-port, and 8-port 10-Gigabit Ethernet Fiber Modules. The answer, I believe, is yes. Switching Modules. WS-SUP720-3B Supervisor Engine 720 with PFC3B daughter card and. Options. Product. See more detailed modulesThe J9309A four-port SFP⁠+ module only supports 10G transceivers. Cat ChassisFanTray+Sup2T;IP SvcsONLY incl VSS REMANUFACTURED. 11-17-2016 05:43 AM - edited ‎03-08-2019 08:11 AM. VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4. The 9-slot Cisco Catalyst 6509-E Switch provides high port densities that are ideal for many wiring closet, distribution, and core network as well as data center deployments. VS-C6513E-SUP2T5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR. Regards. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. 1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1834Z38M 3 20 DCEF2T 4 port 40GE / 16 port 10GE WS-X6904-40G SAL1828WCJZ. 098a. VSS . 00 1. 5 VS-SUP2T-10G 435. 11-17-2016 05:43 AM - edited ‎03-08-2019 08:11 AM. WS-X6816-10G-2T: 16-port 10 Gigabit Ethernet Fiber Module with DFC4 (Figure 1) and WS-X6816-10G-2TXL: 16-port 10 Gigabit Ethernet Fiber Module DFC4XL (Figure 1) Backplane connection: Connects to the switch fabric using dual full-duplex 20 Gbps switch fabric channels (40 Gbps total). I am running into these errors below. 4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19038DU0. 我的引擎卡是Sup2T,重启系统时,没有提示这个命令,按ctrl + break按键进入不了rommon模式去 00:00:03: %OIR-6-CONSOLE: Changing console ownership to route processor 0 HelpfulThe Cisco SFP-10G-SR-X is a multirate * 10GBASE-SR, 10GBASE-SW and OTU2/OTU2e module for extended operating temperature range. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. The link below gets you started:i have a Cisco 6504E with a VS-S2T-10G and a small problems with two card: *Mar 25 17:20:06. VS-S2T-10G . SAL1526HBA1. It has 1G fiber and 1/10G fiber options, as well as several 10/100/1000 and 100/1000/2. Solved: Hi, in our core WS-C6509-E (IOS Software- 15. 2 Ok. C6880-X-LE-16P10G. 5164 5 5 VS-S2T-10G Line Card Compatibility jamaludeen_s Beginner Options 10-01-2017 06:38 AM - edited ‎03-08-2019 12:13 PM Hi, I am configuring C6807 series. 4 Ok 7 Distributed Forwarding Card WS-F6K-DFC4-A SAL1927JC3V. $53,995. VS-SUP-2T-10G. Price Trend of VS-S2T-10G. 5. Vs-Sup2T-10G ECI: 190153 CLEI: CMUCACYBAC List/Series: System: GET STARTED. . Manufactured by Cisco. Table 2 Supervisor Engine 2T Models; Supervisor Engine 2T Product Numbers Description VS-S2T-10G The VS-S2T-10G is shipped with a factory-installed PFC4 daughter card (VS-F6K-PFC4) and a factory-installed MSFC5 daughter card (VS-F6K-MSFC5). The Supervisor Engine 2T is designed to deliver higher performance, better scalability, and. Cisco Catalyst 6500 4-Port 10 Gigabit Ethernet Fiber Module. UDI=VS-SUP2T-10G:SALxxxxxxxx there is no service impact and we won't be fixing it for now. 37 on on. VS-S2T-10G | The Cisco Catalyst 6500 Series is the flagship among switching platforms. Catalyst 6503-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community. Default Control Plane Policy on Catalyst 6500/Sup2T and Catalyst 6880 Configuration Example ;VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA . Sup Engine is not able to sync each other and standby Sup restart when the active Sup is detach. Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS-Product Migration Options. In VSS mode, unsupported. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible >> with Supervisor DFC. 2656 5 5 Compatible replacement part for VS-SUP2T-10G Go to solution pp086r Beginner Options 07-14-2017 07:34 PM - edited ‎03-03-2019 08:36 AM Hello. 00. 56. Conditions: reload. Beginner. CMP should be treated as a separate entity and there is no replication of such information between supervisors. Operating temperature. Free PDF of Cisco VS-S2T-10G. 08-22-2012 04:03 PM. ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. Read line card data sheet. Uplink ports (PORT 1 through PORT 5) ·Supervisor Engine 2T has five uplink ports: ·Two 10GBASE-X ports·Three 1000BASE-X ports·Each uplink port has a link LED associated with it. Free shipping. Note To upgrade from VS-S2T-10G to VS-S2T-10G. Call us 805. I suggest deploying it on a few. 652); SFP-10G-LR, supports 10 km on standard single-mode fiber (SMF, G. 2 8 DCEF2T 8 port 10GE WS-X6908-10G SAL190696FB. The images may differ slightly from the original and are used for illustration. For a quote or to request more information, please complete the form. Configure the virtual switch links. The Gigabit Ethernet Copper. new#show inventorySupervisor Model VS-SUP2T-10G . 18. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. Sup2T is totally different from Sup2. We started receiving the following errors : from show log : %C6KENV-4-MINORTEMPALARM: EARL 7/0 device-1 temperature crossed threshold #1(=110C). It works fine but ACL and route-map counters not incrementing. ChiefTeam538. g. K. The last day to order the affected product(s) is October 30, 2020. 86 120. ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. Does anyone know how to enable it? comments sorted by Best Top New Controversial Q&A Add a Comment blacksheep5405 • Additional comment actions. Consider switching to something new: The Cisco Catalyst 9400 Series Switches offer greater speed, performance and security. Cisco VS-S2T-10G Datasheet PDF Download the datasheet of Cisco VS-S2T-10G. $47,000. VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4. Les clients ont jusqu'au 30 octobre 2020 pour commander les produits concernés. Hello, I am migrating services from SUP720-3B to VS-SUP2T-10G= and moving to a VSS configuration between a pair of Cat6506 distribution layer switches. 1 12. The VS-SUP2T-10G features a new MSFC5 daughterboard with an integrated IBC and a new single, dual-core MPC8572 PPC RP CPU (with ECC-protected L2 and L3 cache, L1 cache is parity detection capable) that operates at 1. The latter in the former is limited to 80 Gbps per line card slot. I have 3 pairs of 6807 VSS switches. I've done some digging where it seems to be the cards aren't supported by the VS-SUP2T-10G that is install. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1741E42N. Scott Fella. 40-port 25G/10G (SFP28) and 2-port 100G/40G (QSFP28) with C9600-SUP-1. Tray+Sup720-10G; IP Base ONLY incl. No. Global Price in USD. Again, not very familiar with the sup2T, but on a 720 you can specify just a device as part of the boot string, and the boot process will look for any valid image (I believe restricted to the root of the device) and boot it. Define "long distances"? Are we talking about links on fibre? Can you post the complete output to the command "sh interface "?The Supervisor Engine 2T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. 5(1)SY2, page 52 † New Features in Release 15. 10. Compatibility matrix which eludes the CVR-X2-SFP10G module is compatible with the VS-S2T-10G and SFP-H10GB-CU5M but only if the SFP-H10GB-CU5M is version 2. VS-C6509E-S720-10G Catalyst Chassis+Fan Tray+Sup720-10G; IP Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. module 7 RP outlet temperature: 43C. 5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1639NJ7U Mod MAC addresses Hw Fw Sw Status 1 6073. Here are the statistics before the ISSU process: The Catalyst 6500 chassis with Switch ID 1 is Active and the Switch with ID 2 is Standby (Hot). module 5 device-1 temperature: 37C. Please let me know the existing IOS is fine and provide the procedure to fix this issue. 2 8 DCEF2T 8 port 10GE. As the 1G and 2 x 10G ports share the total 20G bandwidth points on the SUP2T, if both 10G ports are used for VSL, the 1G ports can not. The current switches have the same setup as per below: MUK_Core1#sh module. SPA. This document describes the supervisor replacement procedure for Cisco Catalyst 6500 Series switches that run in Virtual Switching System (VSS) mode with Quad-Sup720 or Quad-Sup2T. 611: %LICENSE-6-RECOVERED: The IOS license storage on this device was recovered. Hi everyone, I'm having some difficulty understanding QoS on Sup2T. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1. Upload IOS File to bootdisk: #copy tftp: bootdisk: #copy bootdisk: sw1-slot4-bootdisk: #copy bootdisk: slavebootdisk: #copy bootdisk: sw2-slot4-bootdisk: 2. Product Overview Supervisor Engine 2T-10GE Flash Memory Devices Supervisor Engine 2T-10GE Flash Memory Devices disk0: (active) and slavedisk0: (standby): External CompactFlash Type II slots For CompactFlash Type II flash PC cards sold by Cisco Systems, Inc. ADVANTAGE. bin. Sup Engine : VS-SUP-2T-10G. SW1#sh mod switch 1 Switch Number: 1 Role: Virtual Switch Active ----- ----- Mod Ports Card Type Model --- ----- ----- ----- 1 24 CEF720 24 port 1000mb SFP WS-X6824-SFP 3 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T. Mod Sub-Module Model Serial Hw StatusOverview. 94 56. 5 5 Supervisor Engine 2T. I have this problem too. 30 points of limit switches output; Max. $6,500. the 6513-VS-SUP2T-10G supervisor engines do support VSS. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. Note : the origin-id is prepend to syslog messages sent to REMOTE hosts, so it will. (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP 4 48 CEF720 48 port 10/100/1000mb Ethernet WS. Having a problem bringing up 10GB ports between two Cisco 6509-E VS-SUP2T-10GB , they simply are not comming up Physically. 2 Ok 3 Distributed Forwarding Card WS-F6K-DFC4-E xxx 1. 7 PwrDown. 0021 2. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible with Supervisor DFC. what is the IOS code running, Try below syntax : logging origin-id string <device_hostname>. $43,989. White Paper © 2011 Cisco and/or its affiliates. We have VS-SUP2T-10G for sale, both refurbished and new, at prices typically up to 90% less than the original vendor price. I have two 6807 chassis with VSS architecture. Could someone verify if the IDSM2 is compatibility with the Sup2T (running s2t54-ipservicesk9-mz. 00 Get Discount: 3: 7606S-SUP2TXL-P. 155-1. As per the cisco datasheet both the cards and the supervisor are compatible, just need to confirm this. 11-26-2018 09:12 AM. But in the solt 1 the chassis only detects the 40G. This is a chronological list of the 15. Be aware that you have to also acquire a DFC4-A or DFC4-AXL which is a daughtercard of the line card. 256 Gbps) fabric than the SFM or SFM2, also on the supervisor card, itself. Find software and support documentation to design, install and upgrade, configure, and. pdf - F4F1AS6152AC07. Before we begin configuration and setup of VSS, we would like to install the SUP engine into the switches. 04-16-2017 08:35 AM. It also features a new, separate, out-of-band Connectivity Management Processor (CMP) CPU. The ports are Gi1/5/3 and Gi2/5/3. Price Alert. Cisco OneX Converter Module 5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1731APXD 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G SAL1731APZY 8 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1730AFG9. 03-24-2022 04:27 PM - edited ‎03-24-2022 04:29 PM. Solved: Hi, We've just invested in a pair of Sup2Ts to upgrade a Sup720 6509 chassis but I'm unsure exactly how the management port (s), aka the Connectivity Management Processor (CMP), should be configured (and. Transceiver: X2-10GB-SR (is compatable with Sup2T have already checked on matrix) Modules are up, no erros, all Green , have. A leader in scalability and flexibility, this product family is designed for use. The versatile Cisco Catalyst 6500-E Series Chassis is ideal for addressing high-performance, high- port-density Fast Ethernet, Gigabit Ethernet, and 10 and 40 Gigabit Ethernet applications in all parts of the. Sup2T is totally different from. 1x extensions Yes Yes VLAN and router ACLs and port ACLs Yes Yes 1:1 mask ratio to ACE values Yes Yes Security ACL entries 64K shared for QOS/Security 256K shared for QOS/Security CPU rate limiters (DoS protection) 57 57 uRPF check (IPv4/IPv6) Up to 16 Up to 16 これらのモジュールを Cisco Catalyst 6500-E/6807-XL Supervisor Engine 2T/2TXL(VS-S2T-10G および VS-S2T-10GXL)と連携させれば、キャンパス環境のさまざまなニーズに対応することができます。. Contact Cisco. 10 WS-SUP720 Supervisor Engine 720 with PFC3A daughter card andThis PDN was published on 10/31/2014 and lists all parts with the LTB date of 07/31/2015. Description. When your line card has the DFC4-A installed IT. I recall, the only 67xx card that will not work with a sup2T is the 6708, because it comes with a DFC3 that cannot be replaced (with the DFC4 or a CFC). The two supervisor engines must match exactly. VS. Thank you. 5(1)SY3, page 52 † New Features in Release 15. WS-X6708-10G-3C and WS-X6708-10G-3CXL are the orderable product IDs. A Bridge Connecting IT Hardware to The World Routers. 0. このファミリには、Cisco Catalyst 6800 32 ポート、16 ポート、および 8 ポートの 3. VS-10G is the multi functional smart VARILIMIT with various output options such as digital signal output, analog signal output, motion control and multi preset function. 1200 ports scale support on Sup2T —See this publication:vs-c6509e-sup2t-rf Cat ChassisFanTray+Sup2T;IP SvcsONLY incl VSS REMANUFACTURED. I reviewed the original boot-up process and I can see that the line card is booting up as "Standby". The Cisco Nexus 7000 Series Supervisor2 (Sup2) Module (Figure 3) is based on a quad-core Intel Xeon processor with 12 GB of memory and scales the control plane by harnessing the flexibility and power of the quad cores. interface port-channel 1 change it 2 and remove the 1 form the standby one. 0 (2)EX2 is connected to VSS on WS-X6904-40G linecards with a. Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. Cat 6500 Sup2T with 2x0GbE, 3 x1GbE,MSFC5 PFC4XL 2D barcode. The MSFC3 is an integral part of the Supervisor Engine 720, providing high performance, multilayer switching and routing intelligence. To create to an Instant Access deployment profile, do the following: Step 1 Choose Services > Network Services > Instant Access . Leo Laohoo. Figure 4. 3 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1518CXL4. The documentation set for this product strives to use bias-free language. 1445. Current version is. Product Description. The 6708 line card is oversubscribed 2:1 so you'll never be able to get full 10GbE on all ports. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. Execute the conversion command, which will reboot the switches. CSE. Cisco Catalyst 6500 Catalyst 6500 Sup2T VS-S2T-10G-XL-RF VS-S2T-10G-XL-RF The Cisco Catalyst 6500 Supervisor Engine 2T is designed to deliver higher performance,. Mod Online Diag Status---- ----- 1 Pass 3 Pass 4 Pass 5 Pass 6 Pass . . I use the module together with X2 To Sfp+ Adaptor. we are planning to install C6800-8P10G= Interface Module on our WS-C6509-E (two switches configured on VSS). 39. VS-C6509E-SUP2T. Cisco Nexus 7000 Series Supervisor2 Module. Cisco Catalyst 6500 Series Supervisor Engine 2T Network Module (VS-S2T-10G) 1 product rating. 1. VS-SUP2T-10G-MSFC5 Supervisor Engine 2T with MSFC5 daughter card. 1344. %C6KENV-4-MINORTEMPALAR. The Cisco Catalyst 6807-XL chassis (Figure 1) is built to be capable of delivering up to 11. Options. Replacement. One VSS pair has more C6800-32P10G that the other. Is the following upgrade process correct? 1. The VS-SUP2T-10G features a new MSFC5 daughterboard with an integrated IBC and a new single, dual-core MPC8572 PPC RP CPU (with ECC-protected L2 and L3 cache, L1 cache is parity detection capable) that operates at 1. 3 CPU Daughterboard VS-F6K-MSFC5 xxxxxxxxxxx 3. 5Ghz per core. 0(1)SY VS-S2T-10G Supervisor Engine 2T-10GE with PFC4. 5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR 对于Sup2T,在具有内部代号Eureka的第2层(L2)转发引擎(FE)上执行ELAM 操作 。 请注意,L2 FE数据总线(DBUS)包含L2和L3(L3)查找之前的原始报头信息,而结果总线(RBUS)包含L3和L2查找之后的结果。End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. We have ordered the new SUP2T with the 6816 line cards. 5(1)SY1, page 53 † New. Cisco Supervisor Engine 2T is shipped with a 2-GB DRAM module by default. Yes and no. With VSS, both supervisor engines must be the same. Search for:. I need to enable QoS on these switches, primarily to trust dscp and also to prioritise voice traffic. 423. SPA. Total views 3. MSFC3. CSE NETWORKS. 6 Tbps wired switching capacity, with 8 Bpps of forwarding performance is unleashed with Cisco Catalyst 9600 Series Supervisor Engine 2. The link below gets you started:Options. This product is supported by Cisco, but is no longer being sold. It supports a link length of 26m on standard Fiber Distributed Data Interface (FDDI)-grade Multimode Fiber (MMF). Line Number Item Name Description Service Duration Lead Time Included Item Quantity ListPrice Extended ListPrice Discount % Selling Price 1. Buy or Renew. . Both switches need to run the same IOS version (check with 'sh ver'). can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or is it require a downtime. 07-02-2012 08:42 AM. The front panel is labeled WS-X6708-10GE. VS-C6513E-SUP2T. module 7 device-1 temperature: 40C. >> i have a Cisco 6504E with a VS-S2T-10G and a small problems with two card: >> >> *Mar 25 17:20:06. below is the show inventory on my switch. C6880-X-SUP. – WS-X6816-10G-2T, WS-X6716-10G Oversubscription Mode: 0. In VSS mode, unsupported switching modules remain powered off. I have a C6509 with VS-SUP2T-10G and WS-X6716-10GE with WS-F6K-DFC4-E installed. 50. 00 66% OFF. Also, remember that this is just end of sales and Cisco will still support the existing cards for a few more years. . Cisco 7600 Series routers. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4 MEM-SUP2T-2GB Catalyst 6500. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32 27-Jul-2017. item 5 NEW SEALED CISCO VS-S2T-10G-XL - Sup2T, 2x10GbE, 3x1GbE - LIFETIME WARRANTY NEW SEALED CISCO VS-S2T-10G-XL - Sup2T, 2x10GbE, 3x1GbE - LIFETIME WARRANTY. 1(2)SY10 to a newer release. The VS-S2T-10G is only compatible with the E series chassis so you cannot use it without a chassis upgrade: The WS-SUP720-3B would work, or you could use the VS-S720-10G-3C if you need 10gb ports on the supervisor card. Sup2T 1Gig port transceivers/SFPs not detected causing link up failures. Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C - WS-SUP720-3B= Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3B . I installed Sup2T engine on 7606-x chassis. October 31, 2019 End-of-Sale Date: HW, Accessory End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C, Select 67xx Line Cards, and Accessories 06/Jan/2015. Dear All i wonder what are the features enabled to run in hardware on the VS-SUP2T-10G? Specifically i'm curious about "ip accounting mac-ad" command under the SVI. The two supervisor engines must match exactly. W/VS-F6K-PFC4 DAUGHTER CARD. The new sup2t has been shipped to site, however, the failed sup has already been removed and sent back to Cisco so I dont have the old compact flash card, nor do I have a space chassis to pre-stage the replacement sup. Downloads. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. sup2T (SM) board hang when retrieving rommon after reload. VS-C6509E-SUP2T-RF. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Also, remember that this is just end of sales and Cisco will still support the existing cards for a few more years. SY6. Cisco 7606S Chassis,6-slot, Red System,VS-S2T-10G-XL,2PS. Caveats in Release 15. 2(50r)SYS 15. Default Control Plane Policy on Catalyst 6500/Sup2T and Catalyst 6880 Configuration Example ;5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1825UZQ4 Mod MAC addresses Hw Fw Sw Status 5 503d. 3 12. Doc Preview. Compatibility warranty for accessories cannot be guaranteed. 5 Ok 5 Distributed Forwarding Card WS-F6700-DFC3B SAL124592MR 4. 2(50r)SYS 15. WS-X6824-SFP-2T=. Would anyone be able to confirm that the below line card works with our T2 supervisors? The original ones WS-X6704-10GE= are end of life and can no longer be ordered. BOM. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. vs-c6509ve-s72010g Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. The Gigabit Ethernet Copper Module supports RJ-45. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. 442 12748176 4456882 2860 33. Le centre d’assistance technique de Cisco (TAC) continuera de prendre en charge les clients dont les contrats. module 5 asic-1 temperature: 51C. Cisco announced some new modules for Cat6500 last month. Post Reply Getting Started. 2 8 DCEF2T 8 port 10GE WS-X6908-10G SAL1643QYRY. module 7 asic-1 temperature: 68C. Refurbished. Labels: Labels: Other Switching; 0 Helpful Reply. 11-26-2018 09:12 AM. 2. Labels: Labels: Catalyst 6000; LAN Switching; 0 Helpful Reply. 4 CPU Daughterboard VS-F6K-MSFC5 SAL1941QRV1 3. the 6513-VS-SUP2T-10G supervisor engines do support VSS. module 5 inlet temperature: 22C. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. ROM: System Bootstrap, Version 12. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32. (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP 4 48 CEF720 48 port 10/100/1000mb Ethernet WS. It is compatible with Sup2T. In VSS mode, unsupported switching modules remain powered off. CSCto26539. The Cisco Nexus 93108TC-FX3P Switch (Figure 2) is a compact 1 RU switch that supports 2. 2 8 DCEF2T 8 port 10GE WS-X6908-10G . Up to 25. Log In. VS-SUP2T-10G-MSFC5 Supervisor Engine 2T with MSFC5 daughter card. VS-C6509E-S720-10G Catalyst Chassis+Fan Tray+Sup720-10G; IP vs-s2t-10g-xl-rf The Cisco Catalyst 6500 Supervisor Engine 2T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. The forwarding engine on Supervisor. 71 A; Environment . 711: %DOSFS-5-DIR_ENTRY_CORRUPTION: licdisk:1: has. module 7 RP outlet temperature: 43C. 315. Supervisor Engine 2T 10GE w/ CTS" we used a converter CVR-X2-SFP10G in the core switch and the cable is SFP-H10GB-CU3M However the port is not connected and the led is solid orange . Catalyst 6500 Sup2T; VS-S2T-10G-XL-RF; VS-S2T-10G-XL-RF. Recommended version is. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. Mod Ports Card Type Model Serial No. WS-SUP720 Supervisor Engine 720 with PFC3A daughter card and integrated MSFC3 and switch fabric. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6816 10 GE Line Card and Select Accessories 13-Feb-2017. Mark as New; Bookmark;Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. 8 Tbps. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. VS-S720-10G-3C= Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C-VS-C6513-S720-10G. A true stack delivers a unified data and control plane, in addition to management plane, providing flexibility, scalability, and ease of use because the stack. Switching Modules. CISCO VS-S2T-10G, VS-SUP2T-10G,CMUCAB3BAA SUPERVISOR 2T WITH INTEGRATED SWITCH FABRIC/PFC4 AND 2 PORTS 10GBE. The Cisco Nexus 7700 Switches are the latest extension to the Cisco Nexus 7000 Series modular switches. VS-SUP-2T-10G. Buy Cisco Network Accessory VS-SUP2T-10G. Bias-Free Language. Catalyst 6506-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community. Skip to content. VSS VS-C6509VE-SUP2T Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS Upon LDoS of the Bundle PIDs, customers have the option to book Service Contracts on the individual components of the Bundle, based on components support availability. IPv4 unicast takes 1 entry, IPv6 unicast takes 2 entries, IPv4 multicast takes 2 entries, IPv6 multicast takes 4 entries. Product. 1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G . €5€€€ 5€ Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G€ €€€€ SAL15056BKR Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エン ジン(FE)で ELAM を実行します。L2 FE データ バス(DBUS)に、L2 およびレイヤ4 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1941QX54 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL1825UZLA. 18 191. Cisco annonce la date d’arrêt de commercialisation et de fin de vie de Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. Catalyst 6503-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community content. Equipped with a high performance processor, the MSFC runs layer 2 protocols on one CPU and layer 3 protocols on the second CPU. com is neither a partner nor an affiliate of Cisco, Huawei and Fortinet. N/A. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1825UZQ4 Mod MAC addresses Hw Fw Sw Status 5 503d. Solved: Hi. VS-SUP2T-10G. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. all non-XL or all XL. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. e. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. 15. Catalyst 9300X 10G, 25G, 40G, mGig and 100G Catalyst 9300 Stackwise-1T (480G when stacking with Catalyst 9300 model) 48x 10G (Larger Power Budget) Up to 100G IPsec* (2x hosting resources over models) Catalyst 9300 10G, 25G, 40G and mGig Stackwise-480 48x5G and 24x10G Catalyst 9300L Stackwise-320 12x10GI am preparing to do an upgrade from Sup720 to Sup2T on a Catalyst 6509E. 0 Ok 5 Distributed Forwarding Card WS-F6K-DFC4-A SAL1930L1G8 2. Im trying to understand the STP limitation of the Cat 6500 running Sup2T with IOS15. VS-10G.